Features: 45' Max Lift Height, 500 lb. Max Weight Capacity, Swivel Basket, 33X15.50-16.5 Tires, Caterpillar C2.2 Engine, Diesel Powered, 4x4
Meter Reading: 2,647 Hours
Serial Number:
Location: Alberta, Canada
Zip/Postal Code:T9K 0K4
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Touch up paint; Scratches; Chips; See photos for condition
Sheet Metal (fiberglass) Condition Dents; Scrapes; Cracks; Surface rust in areas; See photos for condition
Operators Manual Yes
ANSI Guidelines No
General Appearance #1
 
Control Station Ground
Hour Meter 2,647 hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Function Controls
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Engine Warning Lights Operational
Safety Alarm Operational
Limited Function Check The main components are in place and operational.
Hour Meter
 
Control Station Upper
Control Console
Horn Operational
Emergency Shut Off Switch Loose knob; Functional
Safety Control Foot Switch Operational
Function Controls
Engine Warning Lights
Limited Function Check The main components are in place and operational.
Control Station Upper #1
 
Engine
A propane fuel tank will not be included with this unit at the time of sale. HAZMAT Certificates may be required for transport. IronPlanet is not responsible for the disposal of any remaining product or residue.
Emission Control Label US EPA certification label
Blow by @ idle (subjective observation) Minimal
Fuel System Operational
Exhaust System Leaks at connections
Radiator/Oil Cooler
Oil Leaks Fluid Accumulation: Valve cover; Fluid Accumulation: Side of engine
Fuel Leaks None Seen
Cooling System Leaks None seen
Limited Function Check The engine started and ran. See oil report.
Emission Control Label
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Drive Motors
Final Drives
Limited Function Check The drivetrain functioned without a load.
 
Hydraulics
Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulic) Cracks and cuts on some hoses; Weathered
Steering Cylinders Minimal pin and bushing movement
Limited Function Check The hydraulic system was operational without a load. See oil report.
Hydraulics #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Steering Linkage Minimal movement
Frame Condition
Brake System
Tire Condition Minor cuts and gouges; Foam filled; Hardware embedded in tire
Wheel Condition
Wheel Studs, Nuts, Lugs
Turn-table Bearing Performs within tolerance expected for age and hours
Bottom Covers
Swing Motor
Boom Condition
Boom Wear Guides
Cable Tray Ladder
Work Basket
Chassis #1
Oil Sample Analysis Engine Hydraulic
date of analysis Jul 06, 2012 Jul 06, 2012
Silicon 3 PPM 7 PPM
Lead 0 PPM 2 PPM
Tin 0 PPM 0 PPM
Copper 3 PPM 7 PPM
Aluminum 0 PPM 1 PPM
Silver 0.1 PPM 0 PPM
Nickel 0.7 PPM 0.2 PPM
Chromium 0.2 PPM 0.2 PPM
Iron 4 PPM 9 PPM
Glycol NEG N/A
Water NEG NEG
Fuel <5% N/A

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2013 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet℠, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.