Back to Search Results / 1998 Genie S-60 Telescopic Boom Lift
 

1998 Genie S-60 Telescopic Boom Lift (#406034)

Search for other Aerial Work Platforms items

Winning Bid: US $9,500  
# of Bids: 17   View Bid History
Sold on: : 8/23/12
Auction Type: Featured Auction
SOLD!
Features: 60' Max Lift Height, 500 lb. Weight Capacity, 94" Long x 34" Wide Basket, Swivel Basket, 15-19.5 Tires, Deutz F4L 1011F Engine, 4x4
Meter Reading: 2,355 Hours
Serial Number:
Location: Virginia, United States
Zip/Postal Code:23233-7300
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Scratches; Chips; See photos for condition
Sheet Metal (fiberglass) Condition See photos for condition
Hand Rails See photos for condition
Operators Manual Yes
ANSI Guidelines Yes
General Appearance #1
 
Control Station Ground
Hour Meter 2,355 Hours; Operational - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Gauges Operational
Function Controls Not operationally checked
Oil Pressure The gauge registers in the operating range. 65 PSI
Safety Alarm Operational
Limited Function Check (cs) The main components appear to be in place but were not operationally checked. There is no key with this machine.
Hour Meter
 
Control Station Upper
Control Console Overspray
Emergency Shut Off Switch Functional
Safety Control Foot Switch Operational
Function Controls
Limited Function Check (cs) The main components are in place and operational.
Control Station Upper #1
 
Engine
A propane fuel tank will not be included with this unit at the time of sale. HAZMAT Certificates may be required for transport. IronPlanet is not responsible for the disposal of any remaining product or residue.
Emission Control Label US EPA certification label
Blow by @ idle (subjective observation) Visible
Starter Operational
Turbo or Blower Operational
Fuel System Operational
Exhaust System No visible damage
Oil Leaks None seen
Fuel Leaks There is a dripping leak at the fuel line.
Limited Function Check (Engine) After jump starting the engine ran. See oil report.
Emission Control Label
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Drive Motors
Final Drives Fluid accumulation
Limited Function Check The drivetrain functioned without a load.
Drivetrain #1
 
Hydraulics
Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulic)
Steering Cylinders Minor to moderate pin and bushing movement
Boom Lift Cylinder Minor to moderate pin and bushing movement
Basket Tilt Cylinder
Basket Rotator Motor
Stabilizer Cylinders Minor to moderate pin and bushing movement
Limited Function Check The hydraulic system was operational without a load. See oil report.
Hydraulics #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Steering Linkage Minor to moderate movement
Frame Condition
Brake System The brake system functioned, stopping and holding the machine.
Tire Condition See photos; Minor cuts and gouges
Wheel Condition
Wheel Studs, Nuts, Lugs
Turn-table Bearing Performs within tolerance expected for age and hours
Swing Motor
Boom Wear Guides Dry and worn
Work Basket Control decal damage/overspray
Chassis #1
Oil Sample Analysis Engine Hydraulic
date of analysis Aug 07, 2012 Aug 07, 2012
Silicon 7 PPM 6 PPM
Lead 0 PPM 1 PPM
Tin 0 PPM 0 PPM
Copper 1 PPM 4 PPM
Aluminum 3 PPM 3 PPM
Silver 0.1 PPM 0.1 PPM
Nickel 0.7 PPM 0 PPM
Chromium 2.5 PPM 0.6 PPM
Iron 28 PPM 3 PPM
Glycol NEG N/A
Water NEG NEG
Fuel <5% N/A

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2013 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet℠, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.